Baurecht
Latest

Scaffold handover on a construction site: competent initial inspection and records

Which competent inspection is required before a scaffold is used, when weather or interruptions trigger a repeat check and when records must be kept.

BRANDAUER Rechtsanwälte
Your law firm

BRANDAUER Rechtsanwälte

Salzburg law firm for real estate, construction and corporate law

Every matter is handled by a coordinated team of lawyers, legal staff and specialists. In construction cases we look at contract, evidence, deadlines and commercial consequences together.

28 September 2026 · Mag. Bernhard Brandauer, Rechtsanwalt

A construction company often takes over a scaffold erected by another company. Before anyone uses it, the parties must distinguish the inspection carried out by the scaffold erector from the inspection required of the scaffold user.

Section 61 of the Austrian Construction Work Protection Ordinance, BauV, separates these responsibilities. After completion, a competent person of the scaffold erector must inspect the scaffold. Before first use, a competent person of the scaffold user must inspect it for obvious defects. Further inspections apply to specific scaffold types and events.

This article explains the statutory inspection events, the two roles and the documentation that matters in practice. A scaffold handover does not by itself amount to contractual acceptance and does not replace the assessment of other construction-site risks.

Assess your situation

Which scaffold inspection is required now?

Answer a few short questions about your role and the event. You will receive an initial orientation on first-use, repeat inspections and records.

Already know you want to get in touch? Go straight to the enquiry form.

01 Question 1

What is your role in the scaffold handover?

The BauV distinguishes between the scaffold erector and the scaffold user.

All paths at a glance

Overview of all answers.

01

After completion, the competent person of the scaffold erector must carry out the inspection.

Assign the inspection of the completed scaffold to a person who is competent for the scaffold erector. Pass the relevant information to the future user and make the condition of the scaffold traceable.

This inspection does not replace the scaffold user’s own inspection before first use.

02

Before first use, a competent person of the scaffold user must check for obvious defects.

Arrange the inspection before the first access to the scaffold. Section 61(2) BauV focuses on obvious defects. If such a defect is found, use should stop until safe further work has been clarified.

Record the scaffold area, the event, the competent person and any deviations. If there is a fall hazard under section 7(2)(2) or (4) BauV, records of the inspections must be kept.

03

After the events named in section 61(2) BauV, the scaffold must be checked again for obvious defects before further use.

A longer work interruption, a storm, heavy rain, frost or another period of bad weather creates a new inspection event. A system scaffold must also be checked at least monthly and any other scaffold at least weekly for obvious defects.

The intervals do not replace an event-based inspection. Record the event and the result separately so that the decision to resume work remains traceable.

04

For a suspended scaffold, the suspension structure must also be inspected every day before work starts.

Assign the daily inspection of the suspension structure to a competent person and carry it out before work begins. This additional rule concerns the suspension structure and applies alongside the general inspections under section 61 BauV.

If a defect is found, use should stop until the issue has been assessed and, where necessary, remedied. Record the scaffold, date, person and result so the daily inspection can be allocated to a specific scaffold.

Section 61 BauV separates the erector inspection from the user inspection

After completion, the scaffold must be inspected by a competent person of the scaffold erector. This inspection concerns the completed condition and provides the technical starting point for handing the scaffold to the later user.

A separate inspection is required before first use. It is carried out by a competent person of the scaffold user and is directed at obvious defects under section 61(2) BauV. A general handover statement cannot replace these two distinct steps.

The user should therefore keep the erector inspection and the user inspection separate. The records should show which step took place, when it took place and which competent person carried it out.

Check for obvious defects before first use

Work should not start merely because the scaffold is accessible. Before first use, the competent person of the scaffold user must check whether obvious defects can be identified. The statutory wording describes a check for obvious defects rather than a complete new structural design review.

For the practical handover, the scaffold area, access points, platforms, visible protective equipment and visible changes should be considered together with the intended work. Any deviation should be recorded with its location, time and response.

The inspection relates to the condition before use. Contract questions about responsibility, maintenance or a separate acceptance procedure must be assessed independently from the relevant agreements.

Interruptions, weather and scaffold type trigger further inspections

Section 61(2) BauV lists several events requiring another check for obvious defects: a longer work interruption, a storm, heavy rain, frost or another period of bad weather. Work should resume only after this event-based inspection.

There are also minimum intervals according to scaffold type. A system scaffold must be checked at least once a month and any other scaffold at least once a week. These minimum intervals do not remove the need for an additional check after a specific event.

The records should therefore distinguish an event-based inspection from a regular interval inspection. A single general date may otherwise fail to show whether the reason was a storm, an interruption or the regular interval.

A suspended scaffold requires a daily suspension-structure check

For suspended scaffolds, section 61(3) BauV requires an additional daily inspection of the suspension structure by a competent person before work begins. This rule concerns a specific part of the scaffold and has its own daily timing.

The daily suspension-structure check does not replace the completion inspection or the user inspection before first use. The event-based inspections after interruption or bad weather and the general minimum intervals remain relevant as well.

The handover record should expressly identify a suspended scaffold. The daily entries should be capable of being linked to the scaffold, the date, the competent person and the result.

When records of the inspections are required

Section 61(5) BauV requires records of the inspections under paragraphs 1 to 3 where a fall hazard under section 7(2)(2) or (4) exists. The documentation duty therefore depends on a specific fall hazard and not solely on the fact that a scaffold is present.

Section 7(2)(2) concerns workplaces, standing places and traffic routes at or above water or other substances where there is a risk of sinking. Section 7(2)(4) concerns other workplaces, standing places and traffic routes where the fall height exceeds 2.00 metres.

In practice, the records should identify the scaffold, the inspection date and time, the competent person, the event and whether obvious defects were found. These details structure the evidence but do not remove the need to assess the individual site.

Scaffold handover and contract terms must be considered separately

Section 61 BauV regulates inspections for the protection of employees. It does not automatically determine ownership, cost allocation or the time at which a contractual service has been accepted.

The handover should therefore also record the scope and location of the scaffold, permitted use, the contact for defects, maintenance responsibilities and any changes. If the scaffold is altered, the changed condition must be assessed again by a competent person.

The scaffold inspection is separate from general construction-site coordination and traffic safety for members of the public. For the building owner’s duties under the BauKG, see the article on construction-site coordination. Where there are concerns about a concrete construction instruction, the contractor’s duty to warn may require separate assessment.

Important: A signed handover sheet does not automatically prove that every statutory inspection has been completed. The relevant factors are the role, inspection time, scaffold type, event, competent person and, where a fall hazard exists, the required records.

Inspection matrix

Which inspection belongs to which point in time?

The overview separates the statutory inspection events by role and timing.

Inspections under section 61 BauV during erection, handover and continued use
Inspection step Who inspects? When and what is checked?
Completion Competent person of the scaffold erector After completion of the scaffold
First use Competent person of the scaffold user Before first use, for obvious defects
Repeat check Competent person of the scaffold user After a longer interruption, bad weather and at the minimum interval
Suspended scaffold Competent person Additionally every day before work: suspension structure

Where a fall hazard under section 7(2)(2) or (4) BauV exists, records of the inspections must be kept.

Process

A traceable four-step scaffold handover

A clear sequence prevents the erector inspection from being confused with the user inspection.

  1. 01

    Identify scaffold and roles

  2. 02

    Pass on the completion inspection

  3. 03

    Carry out the first-use inspection

  4. 04

    Record events and intervals

FAQ

Scaffold handover on a construction site: frequent questions

Is the scaffold erector’s inspection enough for first use? +

No. The erector’s competent person inspects after completion. Before first use, a competent person of the scaffold user must also check for obvious defects.

Must a scaffold be inspected again after a storm? +

Yes. Section 61(2) BauV names storms, heavy rain, frost and other periods of bad weather as events requiring another check for obvious defects. Further use should wait until that inspection has taken place.

How often must a scaffold be checked without a specific incident? +

A system scaffold must be checked at least monthly and any other scaffold at least weekly for obvious defects. These minimum intervals do not replace an additional check after a particular event.

What additional rule applies to a suspended scaffold? +

The suspension structure must be inspected by a competent person every day before work starts. This daily inspection is additional to the general inspections under section 61 BauV.

When must records of scaffold inspections be kept? +

Section 61(5) BauV requires records where a fall hazard under section 7(2)(2) or (4) exists. This includes, among other situations, a risk of sinking at or above water or other substances and other workplaces, standing places or traffic routes with a fall height above 2.00 metres.

Topics
scaffold handoverscaffold inspectionBauVinspection recordsconstruction site

Defects, a remuneration dispute, looming litigation?

In construction law, deadlines and evidence decide. Call us directly or send an email, callback within one business day.

Contact

A direct line to the firm.

Address

BRANDAUER Rechtsanwälte GmbH Giselakai 51 5020 Salzburg